1600P CO2 Monitor and Controller for Greenhouse to Automatically Control Fan

Short Description:

Features:

1. It shows real-time readings of CO2, temperature and humidity;

2. The split design between the CO2 sensor and the host makes the detection position free from the limitation of the operating position, and the use scene is more flexible;

3. Controls start-up and shutdown of ventilation fan when CO2 concentration is higher or lower than the setpoint;

4. Super large LCD to monitor CO2 concentration, time&date at the same time;

5. Three-level CO2 quality indicator: Good, Normal, Poor;

6. NDIR sensor for CO2 monitoring with self-calibration;

 


  • MOQ: 1 Piece
  • OEM/ODM: Yes
  • Price: Please contact us for the latest quotation
  • Supply Ability: 100000pcs/month
  • Port: Shenzhen
  • Product Detail

    Product Tags

    1600P-CO2-Monitor-and-Controller-for-Greenhouse-to-Automatically-Control-Fan-05

    Where do CO2 Monitor and Controller use?

    Schools, Greenhouse, Office buildings, Factories, Hospitals, Hotels, Transportation lines, Grow Room, Glass House, Plants Factory, Mushroom / Paprika / Strawberry / Tomato Farming Cold Storage, Places where CO2 is generated at high levels.

    Measurement

    Specifications

    Operating Temperature

    32°F to 122°F (0°C to 50°C)

    Storage Temperature

    -4°F to 140°F (-20°C to 60°C)

    Operating & Storage RH

    0-95%, non-condensing

    CO2 Measurement

    Accuracy at 0~3000ppm

    ±50ppm or ±5% of reading, whichever is greater

    Accuracy over 3000ppm

    ±7%

    Repeatability

    20ppm at 400ppm (standard dev. of 10 readings in 1 minute)

    Measurement Range

    0-5000ppm / 0-10000ppm

    Display Resolution

    1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000)

    Temp Dependence

    ±0.2% of reading per °C or ±2ppm per °C, whichever is greater, referenced to 25°C

    Response Time

    <2min for 63% of step change or <4.6min for 90% step change

    Warm-up Time

    <20 sec

    Temp Measurement

    Operating Temperature

    32°F to 122°F (0°C to 50°C)

    Display Resolution

    0.2°F (0.1°C)

    Response Time

    <20min(63%)

    RH Measurement

    Range

    5-95%

    Accuracy

    ±5%

    Resolution

    1% on Main Reading, 0.1% on Max Min Reading

     

     

    Power Requirements

    160mA Peak, 40mA average at 5.0V

    Output voltage of valve

    110-220v

    Dimension

    120*90*33.5mm (4.7*3.5*1.3 inch)

    Weight

    103g ( 3.6oz) Device only, AC Adapter not included